Inicio > Equipos de Emergencia y Quirófano > Respiradores / Ventiladores > UCI Respirador Artificial Móvil YSAV70B

UCI Respirador Artificial Móvil YSAV70B

Respirador Artificial móvil con pantalla LCD 10.4", Modos de ventilación: A/C,IPPV,SIPPV,IMV,SIMV,PEET,MANUAL,SUSPIR,SPONT
  • Código de: YSAV70B
  • Marca:YSENMED
  • Tienda Precio: Inquiry
  • Productos, haga clic en cuenta:951
  • 销量:最近售出 3
  • Calificación del usuario:: (已有0条评论)
  • Compra el regalo del producto:0 Integral
  • MOQ:1
  • Nave de:China Guangdong
  • Envío: Within 5-10 days after payment
Cantidad: -+

Detalles del producto

Métodos de envío

Métodos de pago

UCI Respirador Artificial Móvil YSAV70B


Mobile ICU Ventilator Machine UCI Respirador Artificial Móvil YSAV70B uci icu precio venta compra oferta calidad económico costo coste hospital clinica quirófano cirugía ambulancia urgencias operación barato respirador

TECHNIQUES SPECIFICATIONS
Physical specifications
Display 10.4'' LCD Display
Mode: pneumatically powered and electrically controlled system
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve <12.5 kPa
Respiratory Rate 1 ~ 99 bpm
Oxygen Concentration 21% ~ 100% 
Maximum Minute ventilation ≥18L / min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
Ventilator compliance ≤30 Ml/kPa
PEEP: 0 ~ 1.0 kPa
Ptr: -10 ~ 10 hPa
IMV frequency: 1~20 bpm
I/E Ratio: 4:1~1:4, Has the inverse ratio ventilation
Tidal Volume Setting Range: 50~1500ML     Display Range: 0~2000ml ;   resolution ratio: 10ml
Inspiratory Plateau: 0~1s
Maximum Safety Pressure ≤ 6.0kPa
Sigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
Pressure limit range: 1.0~ 6.0kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0 kPa
±0.2 kPa
Ventilation Volume alarm: ≥ 18L/ MIN
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz; 
Attention: the AC power supply used for the anesthesia machine must be well     grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.
Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
Power On Self Test Self test before working, assure it's working normally.

Previous: Ventilador Médico Móvil Hospitalario UCI YSAV90A
Next: Ventilador Médico UCI Pantalla LCD HD 5.7 "(Móvil) YSAV201M
Shipping methods
Payment methods
Obtener Precio
Anote su demanda a continuación y nos pondremos en contacto con usted dentro de 24h!
Tu nombre: *
Compañía: *
Dirección: *
Email: *
Teléfono: *
Contenido: *
Código: captcha *
 
YSENMED Ingeniero ofrece capacitación en máquinas en Myanmar
Del 1 al 3 de junio, nuestro ingeniero fue enviado al nuevo hospital de un gran cliente en Myanmar para capacitar al operador de la máquina y el mantenimiento de la máquina de anestesia y el ventilador.
Time: 2018-06-06 11:52:37
Zenmed ofrece equipos médicos para la cena en el nuevo hospital de Myanmar, incluidos equipos de quirófano, autoclave, mobiliario hospitalario, etc.
Time: 2018-04-11 14:37:44